- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
Ballmer, Stefan_W (2)
-
Abbott, Rich (1)
-
Adams, Carl (1)
-
Adhikari, Rana_X (1)
-
Ananyeva, Alena (1)
-
Appert, Stephen (1)
-
Arai, Koji (1)
-
Areeda, Joseph_S (1)
-
Asali, Yasmeen (1)
-
Aston, Stuart_M (1)
-
Austin, Corey (1)
-
Baer, Anne_M (1)
-
Ball, Matthew (1)
-
Banagiri, Sharan (1)
-
Barker, David (1)
-
Barsotti, Lisa (1)
-
Bartlett, Jeffrey (1)
-
Berger, Beverly_K (1)
-
Betzwieser, Joseph (1)
-
Bhattacharjee, Dripta (1)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Ground-based laser interferometric gravitational wave detectors (GWDs) consist of multiple optical cavity systems whose lengths need to be interferometrically controlled. An arm-length stabilization (ALS) system has played an important role in bringing these interferometers into an operational state and enhancing their duty cycle. The sensitivity of these detectors can be improved if the thermal noise of their test mass mirror coatings is reduced. Crystalline AlGaAs coatings are a promising candidate for this. However, the current ALS system with a frequency-doubled 532 nm light is no longer an option with AlGaAs coatings because the 532 nm light is absorbed by AlGaAs coatings due to the narrow bandgap of GaAs. Therefore, alternative locking schemes must be developed. In this Letter, we describe an experimental demonstration of a novel ALS scheme, to the best of our knowledge, which is compatible with AlGaAs coatings. This ALS scheme will enable the use of AlGaAs coatings in current and future terrestrial gravitational wave detectors.more » « less
-
Brooks, Aidan_F; Vajente, Gabriele; Yamamoto, Hiro; Abbott, Rich; Adams, Carl; Adhikari, Rana_X; Ananyeva, Alena; Appert, Stephen; Arai, Koji; Areeda, Joseph_S; et al (, Applied Optics)Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nanometer scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduce the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power buildup in second generation gravitational wave detectors (dual-recycled Fabry–Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and, hence, limit GW sensitivity, but it suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises.more » « less
An official website of the United States government
